How is using multiple microinverters more reliable than using one string inverter?
With a string inverter there is a single point of failure. If the string inverter fails, the entire array is offline. However, with a microinverter each individual PV module has its own dedicated inverter. If the microinverter (or the associated PV module) should fail. only that PV module is offline while the remainder of the system continues to operate. Enphase microinverters have a publicly stated defect rate of 0.05%, which equates to 1 in 2000. Given that the Enphase defect rate is better than most string inverters, this results in a PV installation with higher reliability and a higher overall system uptime over the life of the array.
Additionally, Enphase microinverters have an estimated useful life of more than 25 years, compared with string inverters that typically last around 10 years.
What is the MOQ for each cells and interconnection tabs (Purpose is to string the cell together)?
- Maxeon Gen 3: 1500pcs/box
- Maxeon Gen 5: 1200pcs/Box
- Interconnection tabs:1200pcs/box
How long does charging take?
This will depend on your panel wattage, your battery watt-hour (Wh) capacity (a measurement of storage capacity) and the weather. A 150 Wh battery will charge faster than a 500 Wh battery because the 500 Wh battery has more storage capacity, therefore requiring more time to fully charge. In addition, a 100-watt panel will charge a battery faster than a 50-watt panel exposed to the same amount of sunlight.
Charging time will be affected by weather, shade, time-of-day, age and use of battery, efficiency of the charge controller, placement of the solar panels, and other operational factors. Be sure to look on your solar-compatible battery for an estimate of charging times as well as panel-wattage compatibility, and always check the charging characteristics of the battery to ensure it’s compatible with the wattage of the panel.
For higher battery capacity (greater than 150 Wh) we recommend using a 100-watt panel. Before doing this, however, please ensure that the battery you are charging is compatible with this wattage and use a compatible charge controller.
What happens during power outages?
Your system will automatically shut down. Safety requirements prohibit the system from producing electricity during a power outage or blackout, because there is a chance that the system could feed electricity into the electric grid while utility workers are accessing the grid. The system will restart automatically when power is restored.
How is the system managed in three-phase? How are imbalances managed?
The Enphase three-phase Q Cable allows balanced and automated power management of each phase. Alternatively, when using three single-phase cables, care must be taken to balance the phases by installing a similar number of panels on each phase.
The Envoy-S communications gateway can also provide phase imbalance monitoring to ensure authorised limits are not exceeded. The Envoy is able to manage PV power production at the microinverter level to maintain balance within set limits.
How many microinverters can you put on a single-phase installation? And a three-phase installation?
In single-phase, 10 microinverters can be connected. In a three-phase installation, up to 30 microinverters can be connected on a single 20A three phase circuit breaker. Larger systems can be constructed with multiple AC branch circuits.